Medium Temperature Recirculated Suction Pipe Label
Item #
AN-1-27
EZ Marker Reads
Medium Temperature Recirculated Suction
Compliance
IAAR Bulletin No. 114

Medium Temperature Recirculated Suction Pipe Label

Size:

Material:

Laminate:

Mounting:

Packaging:

Price:
$3.75
Low Price Guarantee
Qty
Each
  • 1–49
    $3.75
  • 50–99
    $3.55
  • 100+
    $3.30

0 In Stock
Special freight arrangements are necessary.

Need a quote for a large order? Call 800‑274‑5271 or email us.

Product Information

Details

IIAR BULLETIN #114 - 2019 REVISION

Each marker is printed with the appropriate abbreviation, the corresponding physical state and pressure level, and the necessary directional flow arrow. Thereby allowing the installer to mark each location with one quick and easy step.

Ammonia markers have been developed to help contractors comply with ANSI / ASME A13.1-2015 standards for piping identification and IIAR's Recommended Guidelines, Bulletin #114 Identification of Ammonia Refrigeration Piping and System Components 2019 Revision.

Bulletin #114 2019 states that all piping mains, headers and branches should be identified as to the physical state of the refrigerant, i.e. vapor, liquid, etc., the relative pressure level of the refrigerant and the direction of flow. All components of the refrigeration system, e.g. receivers, heat exchangers, accumulators, etc., should also be uniformly identified.

Pipe markers in accordance with Bulletin 114, are designed to identify the refrigerant contained within that piping segment (i.e., ammonia) including the physical state of the refrigerant, relative pressure level of the refrigerant and direction of flow.

  1. Ammonia Piping Abbreviations: The 2019 revision contains 31 abbreviations versus 17 contained in the 1991 Guidelines. See full list below.
  2. Color changes: The background color for Ammonia pipe markers shall be Safety Orange, following the color guidelines by ANSI Z535.1 Safety Color Code.
  3. Color changes: The color for the LIQUID physical state has also changed, it used to be Orange and is now Yellow.
  4. Component/ Equipment Marker Abbreviations: in the 2019 revision IIAR has supplied a list of the most common component abbreviations. See full list below.
  5. Piping Color Scheme: the scope of this new section is to provide a suggested, non-mandatory color scheme beyond a simple 'one color' or 'two color' scheme for ammonia refrigeration piping systems in machinery rooms. The color schemes may also be applied to portions of the refrigeration system beyond machinery rooms. Existing schemes for identification are considered acceptable. In those areas where state codes and government regulations are not conflicted, ammonia refrigerated facilities have the option to implement a company documented piping color scheme.

AMMONIA PIPE MARKER INFORMATION

Ammonia pipe markers will contain or be divided in 5 section or components:

  1. Abbreviation Section: Printed in black
  2. Physical State Section: Either LIQUID or VAPOR
    Printed in yellow for Liquid and sky blue for Vapor
  3. Marker Body: Body color to be Safety Orange and contain the refrigerant "AMMONIA" printed in black
  4. Pressure Level Section: Either LOW or HIGH.
    Pressure in excess of 70 psig will be considered to be high pressure and printed in black letters on a red band.
    Pressure equal to or less than 70 psig will be considered to be low pressure and printed in black on a green band.
  5. Directional Arrow: Detachable arrow printed in black.
  • 5 Components of an ammonia pipe marker

PIPE MARKER SIZE CHART

The following chart shows the recommended pipe marker letter height and marker size based on the outside pipe diameter of the pipe to be identified and the distance between the viewer and the pipe.

Considering these factors, the size of the pipe marker and lettering should be selected to provide quick and positive identification. Pipe location, from a viewer's standpoint, will be different on every installation. Therefore, on-site decisions will be necessary to provide the optimum pipe marking system.

  • Diameter (O.D.) Range Minimum Marker Width Minimum Marker Length Letter Size Physical State Pressure Level
    Up to 1-1/4" 1" 8" 1/2" 1/2" 1/2"
    Greater than 1-1/4" – 2" 1-1/2" 8" 3/4" 3/4" 3/4"
    Greater than 2" – 7" 2-1/2" 12" 1-1/4" 1" 1"
    Greater than 7" – 10" 3-1/2" 24" 2-1/2" 1-1/2" 1-1/2"
    Over 10" 4-1/2" 32" 3-1/2" 2" 2"

Brimar's Stick-On EZ Pipe Markers

  • Illust. of Ammonia Marker for Pipe OD of .75 to 2 inches
    Ammonia EZ Marker Style AN-1
    For pipes with O.D. of 3/4" to 2"

    Legend Size: 3/4"
    Marker Size: 10" x 1-1/2"
    Marker comes with detachable directional arrow
  • Illust. of Ammonia Marker for Pipe OD of 2.5 to 6 inches
    Ammonia EZ Marker Style AN-2
    For pipes with O.D. of 2-1/2" to 6"

    Legend Size: 1-1/4"
    Marker Size: 15" x 2-1/2"
    Marker comes with detachable directional arrow


  • Illust. of Ammonia Marker for Pipe OD of 2.5 to 6 inches
    Ammonia EZ Marker Style AN-3
    For pipes with O.D. of 7" to 10"

    Legend Size: 2-1/2"
    Marker Size: 27" x 3-1/2"
    Marker comes with detachable directional arrow
  • Illust. of Ammonia Marker for Pipe OD of 2.5 to 6 inches
    Ammonia EZ Marker Style AN-4
    For pipes with O.D. Over 10"

    Legend Size: 3-1/2"
    Marker Size: 32" x 4-1/2"
    Marker comes with detachable directional arrow

AMMONIA REFERENCE CHART

A reference chart that fully explains the ammonia refrigeration piping and component identification markers, including the approved abbreviations, should be placed in areas that are conspicuous to operating personnel. Regardless of the piping color scheme selected, a legend or key to the meaning of the colors should be posted in a conspicuous area. The reference chart, legend, or key should be made of durable material that will remain legible.

  • Ammonia Reference Chart Bulleting 114 2019