Custom Supply to Automatic Sprinkler Sign - SPR-CUST-2 by SafetySign.com

You're using the SafetySign.com Easy Design Tool
Having trouble? .

Custom Supply to Automatic Sprinkler Sign

This sprinkler system sign complies with the requirements of NFPA 13. It identifies crucial components of a Fire Sprinkler System and the system's operation.

Customize this Supply to Automatic Sprinklers Sign by adding your own custom valve information in the white area, below the header. You can also upload your company logo/information in the notify area, by selecting one of the three layout options below: text only, text + logo or just your logo.

The sign measures 7-3/4 x 9", manufactured on .020″ Rust-Free Aluminum, and pre-drilled with 4 mounting holes. If a different size or material is required, please call 800-274-6271 for a price quote. All custom sprinkler signs require a minimum quantity of 10 signs per legend.

Loading…
SPRINKLER VALVE INFORMATION
VALVE IDENTIFICATION COPY

We recommend using this area for valve or system idenfication. For example: location, valve id, etc.

VALVE IDENTIFICATION COPY font
VALVE IDENTIFICATION COPY fontsize
VALVE IDENTIFICATION COPY alignment

Text Color Options

Use the color boxes below to change the color of your custom text.

CONTACT INFORMATION WITH TEXT AND LOGO UPLOAD
WHEN VALVE IS SHUT FOR EMERGENCY, REPAIRS, OR FIRE NOTIFY AREA LAYOUT OPTIONS

These layouts will allow you to have a combination of text and image on your sign. The text and logo upload options below will change based on your layout selection.

WHEN VALVE IS SHUT FOR EMERGENCY, REPAIRS, OR FIRE NOTIFY:

On this area we recommend typing your contact information or uploading your company logo including your phone number.

WHEN VALVE IS SHUT FOR EMERGENCY, REPAIRS, OR FIRE NOTIFY: font
WHEN VALVE IS SHUT FOR EMERGENCY, REPAIRS, OR FIRE NOTIFY: fontsize
WHEN VALVE IS SHUT FOR EMERGENCY, REPAIRS, OR FIRE NOTIFY: alignment

Text Color Options
Upload Your Company Logo with or without Your Contact Information

Upload your own, or choose None to leave the image area blank. Uploaded images should be at least 300 DPI or have dimensions of at least 1000 pixels on either side for optimal print quality.

Upload custom image…

Acceptable files: JPEG, GIF, and PNG images only. 2 MB size limit. For any other format, please email the file to sales@brimar.com.

Choose File
PrevNext
Directional Arrows
PrevNext
Fire & Emergency Exit Related Symbols
PrevNext
UPGRADES & OPTIONS
Anti-Graffiti Overlaminate

These plates do not have an overlaminate option.

Mounting Options

These plates are available only with 4 mounting holes measuring 7/32" (0.218") in diameter.

MISCELLANEOUS
Free Design Service

If you elect to use our free design service, our production team will review your design before it is printed. They will adjust the positioning and sizing of images and text to ensure that your sign or label is not only easy to read and understand but looks visually appealing as well.

Special Instructions

8" Long Heavy Duty Nylon Ties

8" Long Heavy Duty Nylon Ties

Size Materials Price Enter Quantity
Safety Sign - Fence Mounting Accessory 1
8'' Long Nylon $8.50

#16 Stainless Steel Jack Chain

#16 Stainless Steel Jack Chain

Size Materials Price Enter Quantity
50 ft. of Stainless Steel Chain 1
50 ft long Stainless Steel $62.45

#16 Brass Jack Chain

#16 Brass Jack Chain

Size Materials Price Enter Quantity
50 ft. of Brass Jack Chain 1
50 ft long Brass $29.75

7.5″ Black UV Resistant Cable Tie - 50 lb Tensile Strength

7.5″ Black UV Resistant Cable Tie - 50 lb Tensile Strength

Size Materials Price Enter Quantity
Safety Sign - Fence Mounting Accessory 1
7.5" Long UV Black Nylon – 50 lb Tensile Strength $11.95

Brass “S” Hooks

Brass “S” Hooks

Size Materials Price Enter Quantity
Package of 100 1
Brass $23.75

Stainless Steel “S” Hooks

Stainless Steel “S” Hooks

Size Materials Price Enter Quantity
Package of 100 1
Stainless Steel $47.95

Sprinkler System Plates

Sprinkler system plates comply with the requirements of NFPA 13. They identify crucial components of a Fire Sprinkler System and the system’s operation. Failure to properly identify a sprinkler system may not only result in code violations and owner/contractor liability, in a worst-case scenario system failure in a fire emergency may occur.

What is NFPA 13?

NFPA 13 is the standard for the Installation of Sprinkler Systems and provides "a reasonable degree of protection for life and property from fire through the standardization of design, installation, and testing requirements for sprinkler systems, including private fire service mains, based on sound engineering principles, test data, and field experience." The standard applies to water supplies, sprinklers, fittings, piping, valves, all materials and accessories.

Where do sprinkler plates and identification signs need to be installed?

NFPA 13 provides a comprehensive table with a sprinkler system signage summary including sign locations and requirements. Identification signs should be permanently marked weatherproof metal signs, secured with corrosion-resistant wire, chain, or other acceptable means.

Identification sign location varies by type, but in general these should be applied on valves controlling and supplying a sprinkler system. Such locations may include:

  1. Control Valves, Drain Valves, Test Connection Valves, Alarm Valves, Dry Pipe Valves, Preaction Valves, and Deluge Valves
  2. Anti-Freeze Loops, Anti-Freeze Main Valves and Circulating Closed Loop Systems.
  3. Auxiliary Systems
  4. System Control Riser
NFPA 13 Hydraulic-System Sign NFPA 13 Automatic Sprinklers Sign NFPA 13 Main Drain Valve Sign

Verified Secure | Customer Approved

Call Us 800-274-6271