EZ Pipe Marker - F12. Fire Sprinkler Pipe Markers by SafetySign.com.

Fire Sprinkler Pipe Markers

Item #:
F12
Label Reads:
Fire/Smoke Damper
Label Type:
EZ Pipe Marker
Material:
Durable outdoor grade vinyl with adhesive back.
Packaging:
Sold individually.
Availability:
In Stock
Size Materials Quantity/Price Enter Quantity
Adhesive Backed Markers on a Card
1 250 500
8 x 1-1/8'' Style 1XSM for pipe O.D. 3/4'' to 1-1/4'' (1/2'' Text)
$0.55 $0.45 $0.40
8 x 1-1/8'' Style 1SM for pipe O.D. 1-1/2'' to 2-3/8'' (3/4'' Text)
$0.55 $0.45 $0.40
14 x 2-1/4'' Style 1 for pipe O.D. 2-1/2'' to 7-7/8'' (1-1/4'' Text)
$1.30 $1.20 $1.05
24 x 4'' Style 1LG for pipe O.D. 8'' to 10'' (2-1/2'' Text)
$2.70 $2.45 $2.20
32 x 4'' Style 1XLG for pipe O.D. over 10'' (3-1/2'' Text)
$3.85 $3.75 $3.30

EZ Pipe Markers (Stick On Labels)

  • Self adhesive markers you peel and stick
  • Brimar's specially formulated adhesive is applied with a heavy coating to ensure adhesion to a variety of surfaces.
  • Markers should only be applied to clean and dry surfaces.
  • Markers comply with the new ANSI / ASME A13.1 2007 standard if used in conjunction with arrows, all 3 options of assembly shown below are in compliance.
  • Durability: 4 to 7 years outdoors
  • Service Temp: -40 to 180° F
  • Minimum Application Temp: 50° F
  • Surface Prep: Clean & Dry
  • Spec Compliance: ANSI / ASME A13.1 2007
Tape and Arrow

MARKER SIZE, LETTER HEIGHT & MAX. CHARACTERS PER MARKER CHART

The following chart shows the recommended pipe marker letter height and marker size based on the outside pipe diameter of the pipe to be identified. For pipes smaller than 3/4" and for valve identification, the use of a permanent legible tag is recommended.


STYLE 1XSM
For pipes with O.D. of 3/4" to 1-1/4"
Legend Size: 1/2" High
Marker Size: 1-1/8" x 8"
EZ Arrow Size: 1-1/8" x 4"

STYLE 1SM
For pipes with O.D. of1-1/2" to 2-3/8"
Legend Size: 3/4" High
Marker Size: 1-1/8" x 8"
EZ Arrow Size: 1-1/2" x 4"

STYLE 1
For pipes with O.D. of 2-1/2" to 6"
Legend Size: 1-1/4" High
Marker Size: 2-1/4" x 14"
EZ Arrow Size: 2-1/4" x 6"

STYLE 1LG
For pipes with O.D. of 8" to 10"

Legend Size: 2-1/2" High
Marker Size: 4" x 24"
EZ Arrow Size: 4" x 7"

STYLE 1XLG
For pipes with O.D. over 10"

Legend Size: 3-1/2" High
Marker Size: 4" x 32"
EZ Arrow Size: 4" x 7"
Pipe
O.D.
Text
Size
Marker Style Maximum Characters
3/4" - 1 1/4" 0.5" 1XSM 22
1 1/2" - 2" 0.75" 1SM 18
2 1/4" - 6" 1.25" 1 22
8" - 10" 2.5" 1LG 22
Over 10" 3.5" 1XLG 22

BACKGROUND COLOR

Color is the secondary means to identify the contents of a piping system but, many times the most important. The color of the marker should be used to identify the characteristic hazard of the contents of the pipe. The following chart list the classifications shown by ANSI / ASME A13.1 2007 as the suggested color combinations for the pipe markers.

FLUID SERVICE COLOR COMBINATIONS
Fire Quenching Fluids
Safety Red Background / White Legend
Toxic & Corrosive Fluids
Safety Orange Background / Black Legend
Flammable Fluids
Safety Yellow Background / Black Legend
Combustible Fluids
Safety Brown Background /White Legend
Potable, Cooling, Boiler feed, & other Water
Safety Green Background/ White Legend
Compressed Air
Safety Blue Background / White Legend
Defined by the User
Safety Purple Background / White Legend
Defined by the User
Safety White Background / Black Legend
Defined by the User
Safety Gray Background / White Legend
Defined by the User
Safety Black Background / White Legend

LEGENDS & DIRECTIONAL FLOW

The standard regards the legend (wording on marker) to be the primary means of identifying the content of the pipe. The marker should give the name of the contents of the pipe in either the full name or abbreviated form. Arrows are also required to indicate the directional flow of the contents. Legends should be brief, pointed, and simple for greatest effectiveness. Contents should be identified with sufficient additional details such as temperature, pressure, etc., as are necessary to identify the hazard.
Scheme
  • Legends shall be installed close to valves
  • Legends shall be installed near branches and whenever a pipe changes direction.
  • Legends shall be installed before and after all wall, floor and ceiling penetrations.
  • Legends shall be at frequent intervals on straight pipe runs. Brimar recommends 20 ft.
  • Legends shall be installed on pipes to achieve the best visibility.