Florida Roof Truss Sign
Item #
TRUSS-FL01
Sign Reads
R
Sign Design
R For Roof Truss Construction
Compliance
Rule 69A-3.012

Florida Roof Truss Sign

Size:

Material:

Laminate:

Mounting:

Packaging:

Price:
$18.80
Low Price Guarantee
Qty
Each
  • 1–2
    $18.80
  • 3–4
    $16.75
  • 5–9
    $15.30
  • 10–19
    $14.30
  • 20–39
    $12.60
  • 40+
    $10.70
0 In Stock
Special freight arrangements are necessary.

Need a quote for a large order? Call 800‑274‑5271 or email us.

Product Information

Details

A Florida Roof Truss Sign has official truss identification for fire safety and compliance. A Florida Roof Truss Sign is a helpful resource to help protect the health and safety of personnel, and is not a substitute for required protective measures for reducing or eliminating hazards.

Other available signs:

Compliance

State of Florida TRUSS SIGNS (Truss Roof and Truss Floor Assembly Signs)

69A-3.012 Standards of the National Fire Protection Association and Other Standards Adopted.

(1) Except as specifically modified by statute or by the State Fire Marshal’s rules, the Florida specific edition of NFPA 101, the Life Safety Code®, 2006 edition and the Florida specific edition of NFPA 1, the Uniform Fire Code2006 edition, as adopted within Rule Chapter 69A-60, F.A.C., entitled the “2007 edition of the Florida Fire Prevention Code,” are hereby adopted and incorporated by reference and apply to those buildings and structures specified in paragraphs (a) and (b) of subsection (1) of Section 633.022, F.S.

Excerpt from NFPA 101, the Life Safety Code®, 2006 edition and the Florida specific edition of NFPA 1, the Uniform Fire Code 2006 edition:

(6) Notice required for structures with light-frame truss-type construction.

Purpose: The purpose of this rule is to require the placement of an identifying symbol on structures constructed with a light-frame truss component in a manner sufficient to warn persons conducting fire control and other emergency operations of the existence of light-frame truss-type construction in the structure.

(a) Definitions:

  1. “Light-frame truss-type construction” means a type of construction whose primary structural elements are formed by a system of repetitive wood or light gauge steel framing members.
  2. “Approved symbol” means a Maltese Cross measuring 8 inches horizontally and 8 inches vertically, of a bright red reflective color, designed in accordance with image below.

(b) Any commercial, industrial, or any multi-unit residential structure of three units or more which uses horizontal or vertical light-frame truss-type construction in any portion shall be marked with an approved symbol. Townhouses are not multi-unit residential structures and therefore not subject to this rule. Each approved symbol shall include within the center circle one of the following designations:

  1. Structures with light-frame truss roofs shall be marked with the letter “R”.
  2. Structures with light-frame truss floor systems shall be marked with the letter “F”.
  3. Structures with light-frame truss floor and roof systems shall be marked with the letters “R/F”.

(c) The approved symbol shall be placed within 24 inches to the left of the main entry door and:

  1. Be permanently attached to the face of the structure on a contrasting background, or
  2. Be mounted on a contrasting base material which is then permanently attached to the face of the structure.

(d) The distance above the grade, walking surface or the finished floor to the bottom of the symbol shall be not less than 4 feet (48 in).

(e) The distance above the grade, walking surface or the finished floor to the top of the symbol shall be not more than 6 feet (72 in).

(7) In single tenant structures with multiple main entry doors, such as big box retail stores, department stores and grocery stores, the authority having jurisdiction is authorized to require that other main entry doors of the structure be marked with an approved symbol to carry out the purpose in subsection (6) above.

(8) In multiple tenant structures and covered malls with multiple main entry doors, the authority having jurisdiction is authorized to require that other main entry doors be marked with an approved symbol to carry out the purpose in subsection (6) above. In such structures, approved symbols shall be marked on one side only and spaced not closer than 100 feet or at each end of the structure when such structure is less than 100 feet in length.

(9) The owner of each new structure required to comply with this section shall mark the structure with the approved symbol before receiving a certificate of occupancy.

(10) The owner of each existing structure required to comply with this section shall mark the structure with the approved symbol within 90 days of the effective date of this rule section.

(11) Where the owner of the structure and the authority having jurisdiction disagree as to the use of light-frame truss-type construction within the structure, the owner shall be granted not more than 45 days to provide written verification from a licensed engineer or licensed architect; otherwise, the owner shall comply with the rule.

Sign Configuration

  • Florida Truss Construction Signs
SafetySign.com does not recommend or specify the use of a specific safety sign because it does not have knowledge of the hazard(s) our customers are identifying. It is the customer’s sole responsibility to identify the hazard(s) that may be present and select one or more signs (stock or custom) that accurately identify their specific hazard(s) and complies with any applicable federal, state or local laws or regulations, any worksite specific rules or regulations and/or any applicable safety standards (including, without limitation, ANSI and/or OSHA standards). SafetySign.com disclaims any and all liability (excluding liability for our Product Warranty contained in our Terms and Conditions) for any sign selected by a customer and shall not be responsible for any personal injury or property damage resulting from the use of signs purchased from it or for the independent interpretation made of any applicable federal, state or local laws or regulations, any worksite specific rules or regulations, and/or any applicable safety standards (including, without limitation, ANSI and/or OSHA standards). Customer shall indemnify and hold SafetySign.com and its corporate parent and its officers, directors and affiliates harmless from and against any and all claims, loss or expense (including attorneys’ fees) arising from or related to the purchase and use by customer or any third party of any sign purchased by customer from SafetySign.com.